Delta Electronics — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM operation speed achieves stable status, you can modify V(I), and the pulse output from DVP-PM will accelerate or decelerate according to the modification. In this case, the external STOP input signal cannot stop the pulse output from DVP-PM. To stop the pulse output, you have to trigger the STOP function (b0 of D1846 (D1926, D2006). ♦ Timing diagram: Speed T ACC T DEC V MAX Time Start Stop 6. b5 of D1846 (D1926, D2006, D2086): manual pulse generator (MPG) input ♦ b[5] = 1: enabling MPG input. See D1858 ~ D1864 (D1938 ~ D1944, D2018 ~ D2024) for more details. 7. b6 of D1846 (D1926, D2006): enabling zero return mode ♦ b[6] = 0→1: starting zero return.

The motions of zero return vary depending on different current positions (CP) Zero return path: Direction of zero return Negative Limit Switch Positive Limit Switch LSN DOG LSP [4] [3] [2] [1] Zero CP [1]: On the right of zero point and DOG sensor; DOG = OFF. CP [2]: On the right of zero point; DOG = ON. CP [3]: On the left of zero point and DOG sensor; DOG = OFF, LSN = OFF. CP [4]: On the left of zero point; DOG = OFF, LSN = ON. 8. b7 of D1926: Externally triggering single-speed positioning Note: DVP-10PM do not have LSN/LSP signals, therefore the motions on CP[3] and CP[4] are not available. ♦ b[7] = 0→1: Enabling single-speed positioning triggered by external signal(DOG1).

When b7 of D1926 is ON and DOG1 is triggered, single-speed positioning will be executed. In this case, a mask area will DVP-PM Application Manual 3-69 V BIAS