Mitsubishi — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM Speed Start Time DOG 11. b10 of D1846 (D1926, D2006, D2086): enabling 2-speed positioning ♦ When b[10] is triggered and START = ON, the 2-speed positioning mode will be started. The 2 nd -speed positioning will start immediately after the 1 st -speed positioning reaches P(I). ♦ Operation direction: Direction of relative positioning is determined by the sign bit of the value for P(I) (set in D1838, D1918, D1998, D2078). Direction of absolute positioning is determined by current position (CP). Forward running occurs when P(I) is bigger than CP. Reverse running occurs when P(I) is smaller than CP.

♦ The operation speed will be stable after the speed is accelerated from V BIAS to the expected V(I). When P(I) is reached, V(I) will accelerate/decelerate to V(II) and operates in stable speed. Also, when it is approaching P(II) value set in the register, the positioning will start to decelerate to V BIAS and stop. There are P(I)+P(II) pulses generated during the positioning ♦ The registers involved:

D1824 (D1904, D1984, D2054) (V BIAS ), D1840 (D1920, D2000, D2080) (V(I)), D1844 (D1924, D2004, D2084) (V(II)), D1822 (D1902, D1982, D2062) (V MAX ), D1838 (D1918, D1998, D2078) (P(I)), D1842 (D1922, D2002, D2082) (P(II), D1836 (D1916, D1996, D2076) (T ACC ) and D1837 (D1917, D1997, D2077) (T DEC ). Speed Time Start 12. b11 of D1846 (D1926, D2006, D2086): enabling 2-speed positioning interruption ♦ When b[11] is triggered and START = ON, the 2-speed positioning interruption mode will be started. The 2 nd -speed positioning will start immediately when DOG sensor is detected during the 1 st -speed positioning process. ♦ Operation direction:

Direction of relative positioning is determined by the sign bit of the value for P(I) (set in D1838, D1918, D1998, D2078). Direction of absolute positioning is determined by current position (CP). Forward running occurs when P(I) is bigger than CP. Reverse running occurs when P(I) is smaller than CP. ♦ The operation speed will be stable after the speed is accelerated from V BIAS to the expected V(I). When DVP-PM Application Manual 3-72 T ACC V MAX V(I) V BIAS T ACC P(I) V MAX V(I) P(II) T DEC V(II) V(I) V BIAS