Mitsubishi — 5.6 Application Instructions

5 Categories and Use of Basic Application Instructions M1001 D10(BIN 16bit) D10(BCD 4 digits) Auto conversion No variation No variation Shift move D20(BCD 4 digits) Auto conversion D20(BIN 16bit) If D10 = K1234, D20 = K5678 before execution, D10 remains unchanged and D20 = K5128 after execution. Program example 2: When M1168 = ON (in BIN mode) and SMOV instruction is in use, D10 and D20 will not be converted in BCD format but be moved in BIN format (4 digits as a unit)..

M1000 Digit 4 Digit 3 Digit 2 Digit 1 D10(BIN 16bit) Shift move D20(BIN 16bit) Digit 4 Digit 3 Digit 2 Digit 1 No variation No variation If D10 = H1234, D20 = H5678 before execution, D10 remains unchanged and D20 = H5128 after execution Program example 3: 1. This instruction can be used to combine the DIP switches connected to the input terminals without continuous numbers. 2. Move the 2 digits of the right DIP switch (X27~X20) to the 2 digits of D2, and the 1 digit of the DIP switch (X33~X30) to the 1 st digit of D1. DVP-PM Application Manual 5-27 M1168 X D10 K4 K2 D20 K3 103 102 101 100 103 102 101 100 X M1168 SMOV D10 K4 K2 D20 K3