5 Categories and Use of Basic Application Instructions Use SMOV instruction to move the 1 st digit of D1 to the 3 rd digit of D2 and combine the values from two DIP switches into one set of value. 10 1 10 0 10 2 6 8 8 8 X33~X30 X27~X20 PLC M1001 M1000 M1168 (X20~X27)BCD, 2 digits D2(BIN) (X30~X33)BCD, 1 digit D1(BIN) DVP-PM Operation Instruction 5-28 4 2 BIN K2X20 D2 BIN K1X30 D1 SMOV D1 K1 K1 D2 K3