6 Motion Instructions & G-Code Instructions 2. Moving path X Target position Current position 3. Other valid combinations of operands: Y DRV XDD20 FXHH2345 YK456@V4 FYDD0 DRV XKK-345289 FXD100 YDD10Z5 FYDD102 The above instructions are legal, and device D is the register storing the value to be set up. Remarks: Relevant special registers: DVP-PM Application Manual 6-8 D1822, D1823 Maximum speed on X axis. D1822 (low word); D1823 (high word). D1824, D1825 Bias speed of X axis. D1824 (low word); D1825 (high word). D1836 Acceleration time of X axis D1837 Deceleration time of X axis D1902, D1903 Maximum speed on Y axis. D1902 (low word); D1903 (high word). D1904, D1905 Bias speed of Y axis.
D1904 (low word); D1905 (high word). D1916 Acceleration time of Y axis D1917 Deceleration time of Y axis D1982, D1983 Maximum speed on Z axis. D1982 (low word); D1983 (high word) D1984, D1985 Bias speed of Z axis. D1984 (low word); D1985 (high word) D1996 Acceleration time of Z axis D1997 Deceleration time of Z axis