Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions and G-Code Instructions Operands: P 1 : Target position on X axis P 2 : Target position on Y axis P 3 : Target position on Z axis V : Speed for linear interpolation Explanations: 1. Maximum V = V MAX . 2. Range of parameters: (16-bit) K = -32,768 ~ 32,767; H = 0 ~ FFFF; D = 0 ~ 9,999; (32-bit) KK = -2,147,483,648 3. Acceleration/deceleration time and bias speed can be set up in special D. ~ 2,147,483,647; HH = 0 ~ FFFFFFFF; DD = 0 ~ 9,998. 4. Acceleration/deceleration time increases or decreases in proportional to the setting of V MAX . 5. Timing diagram: Speed Time Start 6. The interpolation speed can be monitored by special registers:

D1850 ~ D1851 for X axis; D1930 ~ D1931 for Y axis; D2010 ~ D2011 for Z axis. 7. D1865 is for setting up stop mode with the consideration on the remaining distance (see Remarks for more information). 8. 16-bit devices and 32-bit devices can be used together. 9. Target position is required, but moving speed could be left out. 10. If you set up the target position on the axis without setting up the moving speed, the operation will run at V MAX 11. 20D model only supports 2-axis (X/Y) synchronous interpolation positioning, and therefore there are 6 operand combinations for LIN instruction.

DVP-PM Application Manual 6-9 MON Mnemonic Operands Function Controllers 20PM - 01 LIN X P Y P Z P F V 1 2 3 Linear Interpolation (considering remaining distance) Type Bit Devices Double-Word Devices Notes K H D KK HH DD ƒ LIN instruction supports V, Z index register modification on the devices. ƒ See specifications of DVP-PM for the applicable range of each device. ƒ You can place an M-Code instruction after LIN. P 1 * * * * * * P 2 * * * * * * P 3 * * * * * * F * * * * * * Controllers 20PM - T ACC V BIAS NO. Instruction Operand combination 1 LIN X P 1 2 X P F V 1