Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions and G-Code Instructions The program should be written as: ABS CW XK10000 YK10000 RK5000 FK1000 2. Example (2): Set up absolute coordinate system. Apply CCW counterclockwise helical instruction and set target position of helix as (0, 30, 15), radius = 30.0 (R = ”+“ when radian second. Z 15 End 30 Y 30 X Start The program should be written as: G17; ABS; CCW XK0 YK30 ZK15 RK30 FK100 Points to note 1. For how to set up arc radius compensation, please refer to MON 15 RADC instruction. 2. The arc/helical movement cannot reach 360° 3. Other valid combinations of operands: The below 5 instructions are all legal, and device D is the register storing the value to be set up.

CW XK123 YDD10 RKK450000 FKK50000 CCW XHAABB R350000 F400000@V5 DVP-PM Application Manual 6-21