Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions & G-Code Instructions MON 06 Operands: T : Pause time (unit: 10ms => K100 refers to pausing for 1 second) Explanations: 1. TIM instruction is used for setting up the pause time between one instruction and another instruction. Time TIM 2. Range of parameters: (16-bit) K = 0 ~ 32,767; H = 0 ~ FFFF; D = 0 ~ 9,999; (32-bit) KK = -2,147,483,648 ~ 2,147,483,647; HH = 0 ~ FFFFFFFF; DD = 0 ~ 9,998. Program Example:

. . . Pause for 1 second Ox0 subroutine . . . DVP-PM Application Manual 6-22 Mnemonic Operands Function Controllers 20PM 10PM TIM T Pause Time Controllers 20PM 10PM Type Bit Devices Double-Word Devices Notes K H D KK HH DD ƒ TIM instruction supports V, Z index register modification on the devices. ƒ See the specifications of DVP-PM for the applicable range of each device. ƒ You can place an M-Code instruction after TIM. T * * * * * * TIM K100