Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions & G-Code Instructions Operands: P 1 : Target position on X axis P 2 : Target position on Y axis V : Speed for 2-axis linear interpolation Explanations: 1. The functions of LIN and INTR are the same, except that LIN can set up stop mode, considering remaining distance. 2. Maximum V = V MAX . 3. Range of parameters: (16-bit) K = -32,768 ~ 32,767; H = 0 ~ FFFF; D = 0 ~ 9,999; (32-bit) KK = -2,147,483,648 4. Acceleration/deceleration time and bias speed can be set up in special D. ~ 2,147,483,647; HH = 0 ~ FFFFFFFF; DD = 0 ~ 9,998. 5. Acceleration/deceleration time increases or decreases in proportional to the setting of V MAX . 6. Timing diagram: Speed T DEC Time 7.

The interpolation speed is monitored by special registers: D1850 ~ D1851 for X axis; D1930 ~ D1931 for Y axis. Start 8. Target position is required, but moving speed could be left out, and therefore there are 6 operand combinations for INTR instruction. Remarks: See Remarks of LIN instruction for relevant special registers. DVP-PM Application Manual 6-28 MON Mnemonic Operands Function Controllers 20PM - 10 INTR X P Y P F V 1 2 2-axis Single-Speed Linear Interpolation (ignoring remaining distance) Type Bit Devices Double-Word Devices Notes K H D KK HH DD ƒ INTR instruction supports V, Z index register modification on the devices.

ƒ See specifications of DVP-PM for the applicable range of each device. ƒ You can place an M-Code instruction after INTR. P 1 * * * * * * P 2 * * * * * * V * * * * * * Controllers 20PM - T ACC V MAX Interpolation s NO. Instruction Operand combination 1 INTR X P 1 X P F V 1 Y P 2 Y P F V 2 X P Y P 1 2 X P Y P F V 1 2 2 3 4 5 6