Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions and G-Code Instructions MON 11 Operands: P 1 : Additional distance on X axis P 2 : Additional distance on Y axis V : Operation speed V(I) Explanations: 1. When SINTR instruction is enabled, the operation speed will start from V BIAS and accelerate to V(I) and then operate stably. When the execution encounters DOG signal, it will follow the additional distance set by the instruction and complete the positioning process. 2. Maximum V = V MAX . 3. The first operand of SINTR can be either X axis or Y axis for single speed positioning with additional distance. 4. Range of parameters:

(16-bit) K = -32,768 ~ 32,767; H = 0 ~ FFFF; D = 0 ~ 9,999; (32-bit) KK = -2,147,483,648 ~ 2,147,483,647; HH = 0 ~ FFFFFFFF; DD = 0 ~ 9,998. 5. Acceleration/deceleration time and bias speed can be set up in special D. 6. Acceleration/deceleration time increases or decreases in proportional to the setting of V MAX . 7. The 16-bit devices and 32-bit devices can be used together. 8. Timing diagram: Speed Start Time DOG 9. Both additional distance and moving speed are required, and therefore there are 2 operand combinations for SINTR instruction. Program Example: 1. When X0 = ON, SINTR instruction in OX0 subroutine will be executed. X axis accelerates to 500kHz in 100ms.

DVP-PM Application Manual 6-29 Mnemonic Operands Function Controllers 20PM - SINTR X P /Y P , F V 1 2 1-axis Single-speed Positioning with Additional Distance Controllers 20PM - Type Bit Devices Double-Word Devices Notes K H D KK HH DD ƒ SINTR instruction supports V, Z index register modification on the devices. ƒ See specifications of DVP-PM for the applicable range of each device. ƒ You can place an M-Code instruction after SINTR. P 1 * * * * * * P 2 * * * * * * V * * * * * * T ACC V MAX V BIAS NO. Instruction Operand combination 1 SINTR X P F V 1 Y P F V 2 2