Delta Electronics — 9.2.3.1 Start / Stop Cyclic E-CAM

9 Electrical CAM Slave max =180 ( ) Slave unit Master =360 max ( ) Master unit „ Start Cyclic E-CAM The timing diagram below indicates an operation process of cyclic E-CAM operation with synchronized output position between 60~300. 1. In T1, D1846 bit 13 = ON, cyclic E-CAM is enabled. 2. After the initialization interval of T2, M1812 = ON to indicate the completion of E-CAM initialization. 3. In T3, cyclic operation starts after M1812 = ON. Slave executes with Master constantly according to the E-CAM Data. 4. At the same time, CLR0 outputs according to the synchronized output range. When M1813 = ON, an E-CAM cycle is completed.

User has to reset the flag for indicating the completion of other E-CAM cycles. n n+60 n+300 Slave Position Master position D1846 b13=ON enables cyclic E-CAM M1812=ON, initialization completed CLR0 sync output M1813, E-CAM completion T1 T2 T3 Reset by user „ Stop Cyclic E-CAM There are two ways to stop cyclic E-CAM: 1. When D1846 bit 13 (enabling cyclic E-CAM) = OFF, Slave of E-CAM stops immediately. DVP-PM Application Manual 9-10