Delta Electronics — 9.2.3.1 Start / Stop Cyclic E-CAM

9 Electrical CAM Slave Position n n+60 n+300 Master position D1846 b13=ON enables cyclic E-CAM M1812=ON, initialization completed CLR0 sync output M1813, E-CAM completion Reset by user 2. When M1748 (indicate E-CAM completion) is ON during E-CAM execution, Slave of E-CAM will stop until the current E-CAM cycle is completed. Slave Position n n+60 n+300 Master position D1846 b13=ON enables cyclic E-CAM M1812=ON, initialization completed CLR0 sync output M1813, E-CAM completion M1748, indicate E-CAM completion Reset by user Set by user „ Application Example: Setup: Set up E-CAM Data as below: E-CAM cycle: Master position 0~50000; Control unit: motor system; Sync output:

Master position 20000~30000, CLR0 = ON as control signal. Set up E-CAM Data as the above curve. E-CAM Data can be set up by PMSoft or DTO instruction (Please refer to explanations in 9.4). Connect pulse output terminals (FP+, FP-, RP+, RP-) to X axis MPG input terminals (A0+, A0-, B0+, B0-). In this case, input signals are from output signals of Y axis. DVP-PM Application Manual 9-11