Mitsubishi — 9.4.2 Use DTO / DFROM Instructions to Set up E-CAM Data

9 Electrical CAM E-CAM data of 10,000 points and is set up by CR#0~9999. One set of E-CAM data consists of 2 points including Master and Slave position, and the unit of every point is Dword. For example, 2 sets of E-CAM data include 4 Master/Slave points which requires 8 CRs as the below structure. In addition, for details about single-data real time modification, please refer to 9.4.2.1. Corresponding CAM Data Specified devices Specified CR D0 CR #0 M0Low D1 CR #1 M0High D2 CR #2 S0Low D3 ... CR #3 ... S0High ... D7 CR #7 S1High M: Master position S: Slave position 32 -bit instruction n=4 indicates 2 sets of CAM Data , CR#10000 :

Create rotary cut E-CAM Data [ Explanations ] DVP-20PM provides CR#10000 exclusively for creating rotary cut E-CAM. The user can create and apply the rotary-cut E-CAM by setting up the related machinery parameters according to actual needs. Parameters for rotary-cut E-CAM are as below: DVP-PM Application Manual 9-28 Parameters Data Format Explanations P1 Length of Master Integer Length of the material feeding axis. Unit:mm P2 Length of Slave Integer Length of the cutting axis (cutter length included). Unit: mm. Sync start position When sync function is enabled, the register sets up the sync start position. P3 Length of sync area Integer Length of sync area. Unit: mm.

Sync end position When sync function is enabled, the register sets up the sync end position. P4 Magnification ratio Floating point The speed of master and slave is synchonized in sync area. Calculation method of magnification ratio: F ×3.14×D F ×3.14×D F R D V =V ⇒ 1 1 = 2 2 ⇒ 2 = 2 2 1 2 R R F R D 1 2 1 1 1 where, V (V ) = Master(Slave) speed (mm/ ); 1 2 sec F (F ) = Master(Slave) frequency (Hz); 1 2 D (D ) = Master(Slave) diameter; 1 2 R (R ) = Master(Slave) pulses of single round. 1 2 P5 Max magnification ratio Floating point P6