9 Electrical CAM P6 sets up the rotary cut acceleration curves and the E-CAM curves, and the examples of each curve are as below: Acceleration curves 0: const speed 1: const Acc DVP-PM Application Manual 9-29 curve (Low word) 0:const speed 1:const Acc 2:SingleHypot 3:Cycloid CAM curve (High word) Integer CAM curve selection for different sections in sync area, e.g. start, end: 0: leftCAM: Sync area is on the left side of CAM curve 1: midCAMall: Sync area is in the middle 2: midCAMbegin 3: midCAMend: (When the curve is selected, E-CAM stops automatically when completed) 5: rightCAM: Sync area is on the right side of CAM curve. Note:
when CAM curve 2 or 3 is selected, the langth of Master will be calculated by system. Sync area setting b[13]=1: Create sync area setting. When the function is enabled, P2 and P3 should be filled with start and end position of sync area. b[14]=1: Only single data real-time modification is applicable. b[15]=1: Borrow the data setting of previous E-CAM P7 Results Integer Display the rotary cut E-CAM creating results (when read back): 0: OK 1: Input data is not proper 2: Insufficient length of E-CAM.