9 Electrical CAM M0 M1 „ Application Example 3: Multi-cutter application Setup: distributed to each cutter and the error of Slave will increase as the execution times increase. In this case, In multi-cutter application, such as rotary cut with 3 cutters, the pulses per round of Slave can not be evenly the CAM data of each cutter should be designed respectively and the sum of the data length of 3 cutters should equal to total pulses per round. To meet this requirement, we only need to design the data setting of the first E-CAM once and set up the associated register for borrowing the data setting from the previous E-CAM curve.
By this function, the 3 CAM curves can be well connected and the pulses per round of Slave can be fulfilled. The set values of the 3 E-CAM are as below. DVP-PM Application Manual 9-43 DMOV K10000 D0 DMOV K1000 D100 DMOV K500 D102 DMOV K200 D104 DFLT K1 D106 DFLT K10 D108 MOV K0 D110 MOV H4000 D111 MOV K0 D112 DTO K100 D0 D100 K7 DMOV K-500 D102 DMOV K200 D104 MOV HC000 D111 DTO K100 D0 D100 K7 Parameters SV of 1st rotary cut SV of 2nd rotary cut SV of 3rd rotary cut E-CAM E-CAM E-CAM Length of Master 1000 1000 1000 Length of Slave 333 333 334 Length of sync area 200 200 200 Magnification ratio 1.0 1.0 1.0 Max magnification ratio 10.0 10.0 10.0 Acceleration curve 0 0 0