9 Electrical CAM 2. Set up work modes (X-D1847 Y-D1927 Z-D2007) For multi-axis E-CAM, b12 and b11 of D1847 should be set as 01 (bit11=1). When Y, Z axis are applied, bit11 of D1927 and D2007 should also be set as 1. 3. C200/C204 counter Enable C200/C204 after setting up counting mode of C200/C204. Multi-axis E-CAM applies C200/C204 as the input signal of Master. Counting mode of C200/C204 should match the pulse input pattern of Master. C200/C204 counting mode setting: Note: z U/D: Counting up / Counting down, P/D: Pulse / Direction, A/B: A-phase / B-phase z M1908:
Input signal control of C200 / C204 When M1908 = OFF, the input signal of C200 is controlled by MPG A0/B0 and reset signal is controlled by PG0. In addition, Input signal of C204 is controlled by MPG A1/B1 and reset signal is controlled by PG1.
Input pulse Pulse U A MPGA0 PV of C200 Dir C200 MPGB0 Input pulse D M1200/M1201 B Counting mode selection M1203=1, PG0 C200 reset signal Input pulse Pulse U A MPGA1 PV of C204 Dir C204 MPGB1 Input pulse D B M1204/M1205 Counting mode selection C204 reset signal M1207=1, PG1 DVP-PM Application Manual 9-54 Device C200 Counting Mode Device C204 Counting Mode M1200=0, M1201=0 U/D* M1204=0, M1205=0 U/D M1200=1, M1201=0 P/D* M1204=1, M1205=0 P/D M1200=0, M1201=1 A/B*(Single frequency) M1204=0, M1205=1 A/B(Single frequency) M1200=1, M1201=1 4A/B(Quadruple frequency) M1204=1, M1205=1 4A/B(Quadruple frequency) Deivce C200 Counting Mode Device C204 Counting Mode M1203=1 PG0 M1207=1 PG1