9 Electrical CAM When M1908 = ON, the 3 axes X/Y/Z share the same high speed counter C200. The input signal of C200 is controlled by MPG A0/B0. C200 reset signal is controlled by PG0. Input pulse Pulse MPGA0 U A PV of C200 Dir C200 MPGB0 Input pulse D B M1200/M1201 Counting mode selection C200 reset signal M1203=1, PG0 There are 2 execution patterns of multi-axis E-CAM: 1. Point-to-point Switching Pattern In multi-axis E-CAM, we can separate an M-points E-CAM Data into several sections for realizing real-time CAM data switching between sections. Only one section will be executed for one time and users can add new data into the next section.
For switching to next section, insert an additional point of (0, n1) between the sections. When Master position is detected as 0, set value n1 of Slave position will be the target number for poin-to-point switching. When single section is completed, M1813/M1893/M2053 will be ON and has to be separate the beginning 202 points into 2 sect.ions. clear by user for Indicating next completion. In the below diagram we use an N-point E-CAM Data and 1 2 Resolution: Displacement 200 4 When M100=0, S100=0 4 When M100=0, S100=101 When value of Master is 0, switch to the number set in Slave 5 When M201=0, S201=101 3 When M201=0, S201=0 DVP-PM Application Manual 9-55 E-CAM X-axis No.
Master Slave 0 M0 S0 1 M1 S1 2 M2 S2 ... ... ... 98 M98 S98 99 M99 S99 100 0 0or101 101 M101 S101 102 M102 S102 ... M103 S103 198 ... ... 199 M199 S199 200 M200 S200 201 0 5 101or 0