Mitsubishi — 9.6.1 E-CAM Application on Winding Machine

9 Electrical CAM 9.6.1.2 Hardware Wiring Diagram 24V 0V Slave servo (coil shaft) ASDA series +24V VDD 24V COM+ FP 0+ PLS OA FP 0- /PLS /OA RP 0+ RP 0- /SIGN SIGN /OB OB +24V Master servo (winding shaft) FP 1+ Shielded cable A0+ ASDA series FP 1- A0- VDD 24V B0+ COM+ B0- FP 1+ PLS OA MPG pulses Shielded cable FP 1- /PLS /OA A phase A A1+ RP 1+ RP 1- /SIGN SIGN /OB OB B1+ A1- B phase B1- CLR1+ PG 0+ CLR1- 5-24VDC PG 0 - 5-24VDC PG 1+ CLR1+ CLR1- 5-24VDC PG 1- 5-24VDC In above wiring diagram, we connect output terminal of Y axis (FP1+ 、 FP1-) to the MPG input terminals (A0+ 、 A0-) as the source of Master.

By this wiring method, winding operation of coil shaft (Slave) will not be influenced no matter the winding direction of winding shaft (Master) is clockwise or counter-clockwise. Therefore, in this case we only connect single direction for Master. 9.6.1.3 Create E-CAM Curve After the wiring, create E-CAM Data in PMSoft as below. DVP-PM Application Manual 9-61 START0 STOP0 LSP0 LSN0 DOG0 S/S0 START1 STOP1 LSP1 LSN1 DOG0 S/S0