3 Functions of Devices in DVP-PM *1: Non-latched area cannot be modified. *2: Non-latched area, can be modified as latched area by changing the parameter settings *3: Latched area, can be modified as non-latched area by changing the parameter settings *4: Latched area, cannot be modified *5: DVP20PM00M supports 3-axis linear interpolation and helical interpolation „ Settings of latched and non-latched memory devices: *1: If you set D1200 = 0 and D1201 = 4095, DVP-PM will automatically ignore M1000 ~ M2999 and set M0 ~ M999 and M3000 ~ M4095 as latched area. *2: K-1 refers to default = not latched. *3:
If you set D1210 = 0 and D1211 = 9999, DVP-PM will automatically ignore D1000 ~ D2999 and set D0 ~ D999 and D3000 ~ D9999 as latched areas. DVP-PM Application Manual 3-3 H0000 ~ HFFFF (16-bit operation); H00000000 ~ HFFFFFFFF (32-bit H Hex operation) Displaying floating point value by 32-bit data complying with IEEE754 F Floating point standard. ±1.1755X10-38 ~ ±3.4028X10+38 General purpose Special auxiliary relay M0 ~ M499 M500 ~ M999 M3000 ~ M4095 M1000 ~ M2999 M Default:: not latched Default:: latched Default:: not latched Allocated in the range of “general purpose” M relays (Auxiliary relay) Start:: D1200 (K500)*1 End: D1201 (K999) *1 Some are latched and cannot be modified.
10ms T0 ~ T255 T Default:: not latched (Timer) Start:: D1202 (K-1) *2 End: D1203 (K-1) *2 16-bit count up 32-bit count up/down C0 ~ C99 C100 ~ C199 C200, C204 C208 ~ C219 C220 ~ C255 C Default:: not latched Default:: latched Default:: not latched Default:: latched (Counter) Start:: D1204 (K100) End: D1205 (K199) Start:: D1206 (K220) End: D1207 (K255) Initial General purpose Latched S0 ~ S9 S10 ~ S499 S500 ~ S1023 S Default:: non-latched Default:: latched (Step relay) Start:: D1208 (K500), End: D1209 (K1023) General purpose Latched Special register D0 ~ D999 D3000 ~ D9999 D1000 ~ D2999 Allocated in the range of "general purpose” registers D (Register) Default:: not latched Default::
latched Some are latched and cannot be modified. Start:: D1210 (K200) *3 End: D1211 (K9999) *3