Mitsubishi — 13.5 Explanations on Control Registers

13 CANopen Communication Card „ CANopen Common Mode „ Object Dictionary Parameters 13.5 Explanations on Control Registers „ Parameters for Normal Mode DVP-PM Application Manual 13-5 CR# Function Attribute Data type Data length n76 Deceleration time(ms) of profile position mode R/W Word 1 n77 n78 Profile position settings R/W Word 1 n80 Homing method R/W Word 1 n81 Home offset R/W Word 1 n82 n83 Homing speed R/W Word 1 n84 n85 Speed for Homing after hitting DOG R/W Word 1 n86 n87 Homing acceleration time R/W Word 1 n88 n89 Enable homing R/W Word 1 n90 Target position of interpolation position mode R/W Word 1 n91 n92 Enable interpolation positioning R/W Word 1 CR# Function Attribute Data type Data length 500 CANopen mode switch R/W Word 1 504 Enable heartbeat protocol R/W Word 1 505 Execution status of heartbeat protocol R Word 1 506 Heartbeat status R Word 1 CR# Function Attribute Data type Data length 1006h Synchronization cycle setting R/W DWord 1 1017h DVP-FPMC heartbeat cycle setting R/W Word 1 1400h~143Fh Parameter settings for RPDO R/W Word 3 1600h~163Fh Parameter settings for RPDO data mapping R/W DWord 4 1800h~183Fh Parameter settings for TPDO R/W Word 3 1A00h~1A3Fh Parameter settings for TPDO data mapping R/W DWORD 4 2000h~207Fh PDO data registers R/W Word 4