13 CANopen Communication Card during SDO data transmission, the error code will be stored in CR#073 and CR#074. If CR#073~CR#076 are used at one time, CR#073 serves as LSB and CR#076 as MSB. CR#080 : NMT command [Explanations] When DVP-FPMC is Master, NMT commands can be used to change the network status. Please refer to the table below for the setting format. „ Parameters for A2 mode A2 mode is one of the applications of DVP-FPMC specifically for delta servo drive: ASDA-A2. In A2 mode, there are 4 CANopen nodes ID1~ID4 planned for ASDA-A2, and control registers CR#100~CR#499 corresponding to servo parameters.
CR#100~CR#199 are CRs for Node ID1, CR#200~CR#299 are CRs for Node ID2, CR#300~CR#399 are CRs for Node ID3, CR#400~CR#499 are CRs for Node ID4. Care should be taken on the special index “ n ” in the CR number. The value of index n could be 1, 2, 3 or 4 indicates 100, 200, 300 or 400 corrensponding to the 4 CANopen nodes for ASDA-A2. Control registers for ASDA-A2 application are applicable only in A2 mode. CR#010 : CANopen bus scan [Explanations] Scan CANopen nodes ID1~ID4. b0~b3 of CR#010 correnpond to node1~node4. When the bit is 1, the corresponding node will be scanned and the content of the register will be cleared automatically. Please refer to the table below. CR#020 :
CANopen bus communication status [Explanations] Display the node communication status by 2 consecutive bits: 00: disconnected, 01: connected, 11: ready. Please refer to the table below. DVP-PM Application Manual 13-9 Bit b15~b8 b7~b0 Function Network management command 1: enable node communication 2: disable node communication 128: switch the operation mode 129: reset node communication Node ID of Slave Bit b15~b4 b3 b2 b1 b0 Node ID Reserved Node 4 Node 3 Node 2 Node 1 Bit b15~b8 b7~b6 b5~b4 b3~b2 b1~b0 Node ID Reserved Node 4 Node 3 Node 2 Node 1