Mitsubishi — 3.10 Special Auxiliary Relays [M], Special Data Register [D]

3 Functions of Devices in DVP-PM DVP-PM Application Manual 3-21 OFF MANU AUTO Special Page Function 10M 20D 20M Ø Ø Ø Attrib. Latched Default M number ON AUTO MANU M1250 C250 counting mode (ON: count down) ○ ○ ○ OFF - - R NO OFF - M1251 C251 counting mode (ON: count down) ○ ○ ○ OFF - - R NO OFF - M1252 C252 counting mode (ON: count down) ○ ○ ○ OFF - - R NO OFF - M1253 C253 counting mode (ON: count down) ○ ○ ○ OFF - - R NO OFF - M1254 C254 counting mode (ON: count down) ○ ○ ○ OFF - - R NO OFF - M1255 C255 counting mode (ON:

count down) ○ ○ ○ OFF - - R NO OFF - M1303 High / low bits exchange for XCH instruction ○ ○ ○ OFF - - R/W NO OFF M1304* Enable force-ON/OFF of input point X ○ ○ ○ OFF - - R/W NO OFF 3-43 M1744* Reset M-code of OX subroutine ○ ○ ○ OFF OFF - R/W NO OFF 3-44 M1745 Disable zero return of X axis in OX subroutine ○ ○ ○ OFF - - R/W NO OFF - M1746 Select the start signal of acyclic CAM 0: START0, 1:

PG0 ╳ ○ ○ OFF R/W NO OFF M1748 Indicate CAM completion ╳ ○ ○ OFF R NO OFF M1749 CAM max frequency control ╳ ○ ○ OFF - - R/W NO OFF - M1751* Enable current position write-in function on X-axis ○ ○ ○ OFF - - R/W NO OFF 3-44 M1752 Enable activation at non-zero position ╳ ○ ○ OFF - - R/W NO OFF - Enable acyclic E-CAM immediate stop function (Stop signal: DOG) M1755 Switch the source of Master of acyclic CAM ╳ ○ ○ OFF - - R/W NO OFF - M1756 Enable reference function of synchronized output. X0: CLR0=OFF signal. X1:

CLR1=OFF signal ╳ ○ ○ OFF - - R/W NO OFF - M1757 Remain current speed until meeting limit switch ╳ ○ ○ OFF - - R/W NO OFF - M1760 Radian / degree selection in OX subroutine ○ ○ ○ OFF - - R/W NO OFF - M1761* Stop X axis movement at fixed position ╳ ○ ○ OFF - - R/W NO OFF 3-44 M1792* X axis ready flag ○ ○ ○ ON ON ON R NO ON 3-44 M1793* Error flag of motion subroutine on X axis; (automatically cleared when X axis is re-activated) ○ ○ ○ OFF - - R/W NO OFF 3-45 M1794* Indicate OX M-code is being executed (automatically cleared when OX is re-activated) ○ ○ ○ OFF - OFF R NO OFF 3-44 M1795 Indicate OX M0 code is being executed (automatically cleared when OX is re-activated) ○ ○ ○ OFF - - R NO OFF - M1796 Indicate OX M2 code is being executed (automatically cleared when OX is re-activated) ○ ○ ○ OFF ON - R NO OFF - M1808 Zero flag for OX subroutine ○ ○ ○ OFF - - R NO OFF - M1809 Borrow flag for OX subroutine ○ ○ ○ OFF - - R NO OFF - M1810 Carry flag for OX suborutine ○ ○ ○ OFF - - R NO OFF - M1811 Error flag for OX floating point operation ○ ○ ○ OFF OFF - R NO OFF - M1812 Indicate the completion of CAM initialization ╳ ○ ○ OFF R/W NO OFF M1813 Indicate the completion of CAM ╳ ○ ○ OFF R/W NO OFF M1825 Disable zero return of Y axis ○ ○ ○ OFF - - R/W NO OFF -