Mitsubishi — 3.10 Special Auxiliary Relays [M], Special Data Register [D]

3 Functions of Devices in DVP-PM DVP-PM Application Manual 3-25 OFF MANU AUTO Special Page Function 10M 20D 20M Attrib. Latched Default Ø Ø Ø D number ON AUTO MANU Insterpolation speed of the third axis by G-code, G01. (low word) 6-48 D1331* Max positioning speed (D1330 = K-1) of the third axis by G-code, G00 (high word) ╳ ╳ ○ 0 - - R/W NO NO 6-46 Insterpolation speed of the third axis by G-code, G01.

(high word) 6-48 D1400* Enable interruption ○ ○ ○ 0 - - R/W NO 0 3-43 D1401* Interrupt interval for timer interrupt (ms) ○ ○ ○ 0 - - R/W NO 0 3-43 D1500 FROM/TO data area, corresponding to CR#0 ○ ○ ○ H’6260 - - R NO H’6260 - D1501 ↓ D1699 FROM/TO data area, corresponding to CR#1 ~ CR#199 ○ ○ ○ 0 - - R/W NO 0 - D1700 The executing No. of OX ○ ○ ○ 0 - - R NO 0 - D1702 Step No.

of the executing OX subroutine ○ ○ ○ 0 - - R NO 0 - D1703* The executing M-code ○ ○ ○ 0 - - R NO 0 3-44 D1704 Pause time of OX subroutine ○ ○ ○ 0 - - R NO 0 - D1705 Present pause time of OX ○ ○ ○ 0 - - R NO 0 - D1706 Set value of RPT instruction in OX subroutine ○ ○ ○ 0 - - R NO 0 - D1707 Present value of RPT instruction in OX subroutine ○ ○ ○ 0 - - R NO 0 - D1708 Offset value for target position of X-axis (low word) ○ ○ ○ 0 - - R NO 0 - D1709 Offset value for target position of X-axis (high word) D1710 Offset for distance to center of arc on X-axis (low word) ╳ ○ ○ 0 - - R NO 0 - D1711 Offset for distance to center of arc on X-axis (high word) D1712 Offset value of arc radius (low word) ╳ ○ ○ 0 - - R NO 0 - D1713 Offset value of arc radius (high word) D1724 Offset value for target position of Y-axis (low word) ╳ ○ ○ 0 - - R NO 0 - D1725 Offset value for target position of Y-axis (high word) D1726 Offset for distance to center of arc on Y-axis (low word) Offset for distance to center of arc on Y-axis (high ╳ ○ ○ 0 - - R NO 0 D1727 word) D1736 Pause time (TIM) of O100 ○ ○ ○ 0 - - R NO 0 - D1737 Present pause time (TIM) of O100 ○ ○ ○ 0 - - R NO 0 - D1738 Set value of RPT instruction in O100 ○ ○ ○ 0 - - R NO 0 - D1739 Present value of RPT instruction in O100 ○ ○ ○ 0 - - R NO 0 - D1796* Deceleration speed for continuous interpolation ○ ○ ○ 0 - - R NO 0 3-46 D1798* Percentage value of G-Code moving speed ○ ○ ○ 0 - - R NO 0 3-47 D1799* Input terminal polarity (for X/Y-axis) ○ ○ ○ 0 - - R/W NO 0 3-47 D1800* Status of input terminal ○ ○ ○ 0 - - R NO 0 3-48