3 Functions of Devices in DVP-PM DVP-PM Application Manual 3-24 OFF MANU AUTO Special Page Function 10M 20D 20M Attrib. Latched Default Ø Ø Ø D number ON AUTO MANU receiving data D1124 COM2(RS-485) Definition of start character (STX) ○ ○ ○ H’3A - - R/W NO H’3A COM2(RS-485) Definition of first ending character D1125 ○ ○ ○ H’0D - - R/W NO H’0D (ETX1) COM2(RS-485) Definition of second ending character D1126 ○ ○ ○ H’0A - - R/W NO H’0A (ETX2) D1129 COM2 (RS-485) Communication time-out setting (ms) ○ ○ ○ 0 - - R/W NO 0 - D1130 COM2 (RS-485) Error code returning from Modbus ○ ○ ○ 0 0 - R NO 0 - D1140* Number of right-side modules (max.
8) ○ ○ ○ 0 - - R NO 0 3-42 D1142* Number of input points (X) on DIO modules ○ ○ ○ 0 - - R NO 0 3-42 D1143* Number of output points (Y) on DIO modules ○ ○ ○ 0 - - R NO 0 3-42 ID of function card (0: no card inserted; 3: COM3 card; D1149 ○ ○ ○ 0 - - R NO 0 - 8: 2AD card; 9:
2DA card) D1200* Start address of latched memory for auxiliary relays M ○ ○ ○ - - - R/W YES 500 3-42 D1201* End address of latched memory for auxiliary relays M ○ ○ ○ - - - R/W YES 999 3-42 D1202* Start address of latched memory for timer T ○ ○ ○ - - - R/W YES -1 3-42 D1203* End address of latched memory for timer T ○ ○ ○ - - - R/W YES -1 3-42 D1204* Start address of latched memory for 16-bit counter C ○ ○ ○ - - - R/W YES 100 3-42 D1205* End address of latched memory for 16-bit counter C ○ ○ ○ - - - R/W YES 199 3-42 D1206* Start address of latched memory for 32-bit counter C ○ ○ ○ - - - R/W YES 220 3-42 D1207* End address of latched memory for 32-bit counter C ○ ○ ○ - - - R/W YES 255 3-42 D1208* Start address of latched memory for step relay S ○ ○ ○ - - - R/W YES 500 3-42 D1209* End address of latched memory for step relay S ○ ○ ○ - - - R/W YES 1,023 3-42 D1210* Start address of latched memory for data register D ○ ○ ○ - - - R/W YES 200 3-42 D1211* End address of latched memory for data register D ○ ○ ○ - - - R/W YES 9,999 3-42 D1320* ID of the 1st right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1321* ID of the 2nd right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1322* ID of the 3rd right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1323* ID of the 4th right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1324* ID of the 5th right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1325* ID of the 6th right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1326* ID of the 7th right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1327* ID of the 8th right-side module ○ ○ ○ 0 - - R NO 0 3-43 D1328* Target position (low word) of the third axis control by G-code (G00, G01) ╳ ╳ ○ 0 - - R/W NO NO 6-46 D1329* Target position (high word) of the third axis control by G-code (G00, G01) D1330* Max positioning speed (D1330 = K-1) of the third axis by G-code, G00 (low word) ╳ ╳ ○ 0 - - R/W NO NO 6-46