Mitsubishi — 3.11 Functions of Special Auxiliary Relays and Special Registers

3 Functions of Devices in DVP-PM M1 Example 2: Use the 3 rd set of timer and set up the timing mode as Cycle mode: 1. In O100 main program, design the 3 rd set of high speed timer with cycle timing mode by setting K1M1208 = K5, i.e. b0 = 1, b2 = 1. 2. Execute the program and C208 will start to time the interval between rising edges of the start signal X12. The timed interval will be stored in C209 with the timer resolution 0.01us. Please see the below diagram for the timing diagram: X12 t1 t2 C209 C209 Cycle mode. Unit: 0.01μs The example program of step 1 and step 2 is as below: M1 3. Cycle mode is mainly used in frequency measuring application. Function Group: I/O Modules Detection Number:

D1140, D1142, D1143 Explanations: D1140: Number of right-side modules (AIO, PT, TC, etc.), max. 8 modules can be connected. D1142: Number of input points (X) on DIO modules. D1143: Number of output points (Y) on DIO modules Function Group: Setting Up Latched Area Number: D1200 ~ D1211 Explanations: 1. The specified range between D1200 (start) and D1211 (end) will be set up as the latched area of DVP-PM. 2. Please refer to the tables in 3.1 for more details. DVP-PM Application Manual 3-42 1 MOVP K4 K1M1208 DCNT C208 K10 2 MOVP K5 K1M1208 DCNT C208 K10