3 Functions of Devices in DVP-PM Function Group: Continuous Interpolation Number: D1796, M1036 Explanations: 1. When you use D1796 to set up the deceleration speed (kHz), DVP-PM will compare the set value in D1796 with the actual deceleration frequency then takes the smaller frequency as the transition frequency of continuous interpolation. 2. When D1796 > 0, the continuous interpolation is enabled to form a continous path. Howevert, the function is only effective to G1/G2/G3/LIN/CW/CCW instructions. You can set M1036 = ON (M1036 = K1) to enable continouous interpolation on general application instructions. 3.
When D1796 = K0 (continuous interpolation disabled) the speed will decelerate to 0kHz between each deceleration step regardless of the actual deceleration frequency. See the figure below. Frequency(Hz) 1,000 500 100 200 300 400 Position 4. When D1796 = K500 (continuous interpolation enabled) DVP-PM will compare K500 with the actual deceleration frequency and takes the smaller frequency as the transition speed. See the figure below . Frequency(Hz) 1,000 500 100 200 300 400 Position 5. Continuous path demonstration When D1796 (continuous interpolation) has not been set, the X → Y path will be a right-angle turn. After D1796 is set, the X → Y path will perform a smiith transition.
Program example: G01 X100 F1000; (Block A) Y100; (Block B) Block A: execute moving path of X-axis Block B: execute moving path of Y-axis DVP-PM Application Manual 3-46