3 Functions of Devices in DVP-PM Y Block B Path with smooth transition Path with a right-angle turn X Block A Function Group: Setting up Percentage Value of G-Code Moving Speed Number: D1798 Explanations: 1. When D1798 is set to 100, the G-Code moving speed will be the original speed. When D1798 is set to 1,000, the G-Code moving speed will become 10 times faster than the original speed. When D1798 is set to 50, the G-Code moving speed will decrease to half of the original speed, and so forth. 2. The upper limit of G-Code moving speed is 500k(Hz). When the G-Code moving speed is set to be faster than 500k(Hz), the speed will be set as 500k(Hz) automatically Function Group:
Setting up Input Terminal Polarity (for X/Y-axis) Number: D1799 Explanations: For input terminals below, setting the corresponding bit# to be ON will define the input terminal as NO contact; setting the corresponding bit# to be OFF will define the input terminal as NC contact. 20PM: 10PM: DVP-PM Application Manual 3-47 bit# Input terminal polarity on X axis bit# Input terminal polarity on Y axis 0 PG0 8 PG01 1 MPGB0 9 MPGB1 2 MPGA0 10 MPGA1 3 LSN0 11 LSN1 4 LSP0 12 LSP1 5 DOG0 13 DOG1 6 STOP0 14 STOP1 7 START0 15 START1 bit# Input terminal polarity 0 DOG0