Mitsubishi — 3.11 Functions of Special Auxiliary Relays and Special Registers

3 Functions of Devices in DVP-PM Note *2: Note *3: Note *4: Function Group: Setting up Acyclic E-CAM Number: D1832, D1833, D1834 (not supported by 10PM) DVP-PM Application Manual 3-51 b1 b0 Unit 0 0 Motor 0 1 Machine 1 0 Combined 1 1 Motor unit Combined unit Machine unit pulse um Position pulse m deg pulse 10-4inch pulse/sec cm/min Speed pulse/sec 10deg/min pulse/sec inch/min b2 Multiplication of b3 position data 0 0 100 0 1 101 1 0 102 1 1 103 b5 b4 Description 0 0 Forward pulse + reverse pulse 0 1 Pulse + direction 1 0 A/B phase pulse 1 1 bit# Explanation 6 b[6]=1: Enable PWM mode (1) When the operation command “JOG+ operation” is enabled, PWM will be executed on Y0~Y3.

(2) When the operation command “single speed positioning” is enabled, single speed positioning will be executed on Y0~Y3 with single-phase pulses. (3) PWM pulse width setting: D1838, D1918, D1998, D2078 (4) PWM cycle setting: D1842, D1922, D2002, D2082 8 b[8]=0: Zero return executes in positive direction, i.e. current position(CP) increases b[8]=1: Zero return executes in negative direction, i.e. current position(CP) decreases 9 b[9]=0: normal mode b[9]=1: overwrite mode 10 b[10]=0: DOG signal falling edge triggered b[10]=1: DOG signal rising edge triggered 11 b[11]=0: CP value increases when in forward running; decreases when in reverse running b[11]=1:

CP value decreases when in forward running; increases when in reverse running 12 b[12]=0: Absolute positioning b[12]=1: Relative positioning 13 b[13]=0: DOG signal rising edge triggered b[13]=1: DOG signal falling edge triggered (Valid for single-speed / 2-speed positioning interruption mode) 14 b[14]=0: Trapezoid curve b[14]=1: S curve