SC523 Chassis Manual Chapter 5: Chassis Setup and Maintenance 5-8 Checking the Airflow in the System Proper airflow allows the chassis to keep the server components cooled and prevent damage. Use the following steps to check the airflow after setting up the system or servicing. Checking the Server's Airflow 1. Power down the system and remove the power cord as described in Section 5-2 and remove the cover as described in Section 5-3. 2. Make sure that no cables or foreign objects obstruct airflow through the chassis. Pull all excess cabling out of the airflow path or use shorter cables. For the SC523 chassis, it is recommended that cables run beside the power supply as much as possible. 3.
Make sure there are no objects to obstruct airflow in and out of the server. 4. Do not operate the server without hard drives or dummy drives in the hard drive trays. 5. Use recommended server parts only. 6. Secure each expansion card to the chassis using the card's bracket and the screw previously removed. The control panel LEDs inform you of system status. See the System Interface sec- tion of this manual for details on the LEDs and the control panel buttons. Once the air shroud has been properly installed, do the following: 1. Install the DVD-ROM drive unit and connect the DVD-ROM drive to the moth- erboard. 2. Install the hard drive tray. 3. Securely close the chassis cover.
Installation Complete This completes the setup and configuration of the system. The system fans and power supply are pre-installed in the chassis. In the unlikely event that you need to replace the system fans or power supply, proceed to the following sections. If the chassis will be installed into a rack, proceed to the next chapter for rack instal- lation instructions. 5-12 5-13 5 Figure 5-11. Securing the Expansion Card wi 5. Simultaneously slide the bracket of the expansion plugging the expansion card into the motherboard. thin the Chassis card into the PCI slot, while