SC813M Chassis Manual Chapter 5: Chassis Setup and Maintenance 5-10 Power Supply "R" model chassis feature redundant power supplies. The power supply can be changed without powering-down the server. The SC813M chassis has one 280, 300, 350, 410, 420, 500, 520 or 600 Watt power supply, or comes with two 400 Watt redundant power supplies. The power supplies are auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. 1. Press the release button on the failed power supply.
Changing a Redundant Power Supply 2. Use the handle to gently slide the power supply out the back of the chassis. Changing a 280, 300, 350, 410, 420, 500, 520 or 600 Watt Power Supply 3. Replace the failed power module with another of the same model. 1. Power down the system and unplug the power cord from the rear of the power supply. Open the chassis cover as described in Section 5-3. Lay the chassis on a flat, stable surface and remove the chassis cover. 4. Slide the new power supply module into the power supply bay until it clicks into the locked position. 2. Remove the two screws, located on the end of the power supply bay, as il- lustrated below. Set the screws aside for later use. 3.
Gently slide the power supply out of the back of the chassis. 4. Replace the failed power module with another of the same model. 5. Slide the new power supply module into the power supply bay. 6. Align the holes in the power supply with the holes in the power supply bay and secure the power supply using the two screws which were set aside in step 2. 7. Replace the chassis cover, plug the power cord into the rear of the power supply and power up the system. Release Botton Figure 5-14: Replacing the 400W Power Supply Remove Screws Figure 5-13: Removing the Fixed Power Supply 5-14 5-15