The basic settings for these two modes are described below: 1. Analog speed Set the analog voltage value of the speed command (V-REF, see “Analog Input Circuit” for wiring) that makes the speed of the servo motor rated as the analog speed command gain Pn300. Example: The factory default parameter Pn300 = 600 (6V corresponds to the rated speed (assuming 3000rpm). If the V-REF input voltage is 1V, the speed command corresponds to 500rpm. If 3V is input, the speed command corresponds to 1500rpm.
94 SD700 Series Servo Technical Manual Function Paramete Range Default Unit Communication When code Address enabled Pn300 Analog speed command gain 150~ 3000 600 0.01V / rated speed 0x0300 Immediately This parameter is used to set servo motor speed that should be equal to analog voltage value (V-REF) required for the speed command of the rated value. Caution: Do not apply more than -10V~10V and exceeding this range may cause damage to the driver. Pn301 Analog speed command negation 0~1 0 - 0x0301 Immediately Set the voltage polarity of the analog speed command: 0-Positive polarity: positive voltage corresponds to positive speed command. 1- Negative polarity:
positive voltage corresponds to negative speed command. Pn302 Analog speed instruction filter time 0~ 655.35 0.40 ms 0x0302 Immediately The function could be set to smooth the speed command when one delay filter is applied to the analog speed command (V-REF) input and it does not usually need to be changed. If the set value is too large, the responsiveness may decrease. Please set this parameter while confirming the response. Pn303 Analog speed command dead zone range 0~3 0 V 0x0303 Immediately In the analog speed control, even if the input command is 0V, the servo motor may rotate at a slight speed. This is because there is a slight deviation in the commands inside the servo unit.
This error can be eliminated by setting an appropriate analog speed command deadband range.