Maximum speed ! Note that the acceleration and deceleration time refers to the acceleration from 0 to the maximum speed or deceleration from the maximum speed to 0. It is judged by the maximum speed and not by the rated speed or the given speed. Cautions 5.3.4 Zero Fixed Functions The zero-fixed function means that when the zero-position fixed signal (/ZCLAMP) is ON, the servo lock is performed when the input voltage of the speed command (V-REF) is lower than the speed set by the fixed zero value (Pn501). At this time, the position loop is formed inside the servo unit, and the speed command will be ignored.

Therefore, when used for speed control, the host device does not build a position loop. The servo motor is fixed within ± 1 pulse of the zero position fixing effective position. Even if rotation occurs due to external force, it will return to the zero position. 1. Zero-fixed configuration The signal is not configured in the factory default switch configuration. Therefore, the pin number configuration (0x0C) needs to be performed by parameters Pn601 ~ Pn609. 97 SD700 Series Servo Technical Manual trapezoidal deceleration time 10000 Deceleration time of the set speed is from max speed (corresponding to the motor model) to 0r/min.

When the given speed is more or less than the max speed, the actual deceleration time is calculated in proportion. Target speed Actual deceleration time Actual deceleration time Function code Parameter Range Default Unit Communication When enabled address Pn312 Zero speed clamp mode 0~3 3 - 0x0312 Immediately