The relationship between zero fixed speed thresholds and zero fixed function is shown in the figure below: Speed V-REF speed command Zero position clamp speed threshold Pn313 /ZCLAMP Zero position clamp function The zero-fixed signal is a universally configurable digital input. See “Sequence Input Circuit” for wiring details. 2. Zero-fixed wiring 5.3.5 Rotation Detection Signal When the motor speed is greater than the set value, a digital rotation detection signal (/TGON) is output. 1. Configuration of rotation detection signal This signal is not configured in the factory default digital output configuration.
Please confirm before 98 SD700 Series Servo Technical Manual Speed mode, setting the switching speed zero clamp signal (/ZCLAMP) working mode: 0- Invalid. 1- Speed command is set to 0, not clamped after shutdown. 2- Speed command is set to 0, clamped after shutdown. 3- Speed command is lower than “zero position clamp speed threshold”, and then speed command is set to 0 at first, clamped after stop. Pn313 Zero Speed Clamp Speed Threshold 0~ 10000 10 rpm 0x0313 Immediately Set the zero control switching threshold when “zero speed clamp mode”(Pn312) is set to 3.
Function Parameter Range Default Unit Communication When code address enabled Pn317 Rotation determination threshold 1~ 10000 20 rpm 0x0317 Immediately When the motor speed is higher than the set value, the switch rotation detection signal (/TGON) is output.