VEICHI — SD700 User Manual 20230516

use. The signal is not configured in the factory default digital output configuration. Therefore, the pin number configuration (0x03) needs to be performed by parameters Pn613 ~ Pn615. The output condition is that the signal is output when the current feedback speed (absolute value) of the motor is higher than the setting value of Pn317 (rotation determination threshold). 2. Wiring of rotation detection signals The rotation detection signal is a universally configurable digital output signal. See “Sequence Output Circuit” for wiring details.

Example of optocoupler circuit Controller Example of relay circuit Controller 5V~30V 5.3.6 Consistent Speed The speed coincidence signal (/V-CMP) is a signal that is output when the difference between the speed of the servo motor and the command speed is equal to or lowers than the set value of the speed coincidence range Pn320. Used when interlocking with the upper device. This signal is the output signal during speed control. 1. Configuration of Speed-consistent Signals In the factory default digital output configuration, the signal is configured as CN129 and 30 pin numbers (Pn614=0x02) by default. Please confirm before use.

99 SD700 Series Servo Technical Manual Servo driver SEN OCZ GND 5V T wisted pair S ervo driver SEN OCZ GND Twisted pair Function Parameter Range Default Unit Communication When code address enabled Pn320 Speed consistent range 0~ 100 10 rpm 0x0320 Immediately When the difference between the motor speed and the command speed is lower than the set value, the switch-speed match signal (/V-CMP) is output.