VEICHI — SD700 User Manual 20230516

5.4.1 Quick Guide Torque Control Quick Guide Connect each part properly Internal torque command (Pn400 = 0) Drive panel display is normal Analog torque command Internal torque command Pn410 The Host voltage T system is given a fixed - REF (Pn400=1) Monitoring Un102, receiving torque No Is the actual torque consistent with the given? No follows given changes? Yes See Confirm the wiring (T d etails In " Analog Input Circuit - REF) " Yes Confirm analog torque command Pn404, Pn405, Pn407, Pn413 related settings Enable operation Run response to meet requirements? No No Yes Gain adjustment Is the running the given?

direction same with Instructions" for details See "Adjustment Yes Confirm Pn406 setting direction Q uick E nd Guide 5.4.2 Basic Setting Torque control is the operation method of inputting the torque command to the servo unit and controlling the output of the servo motor through the size of the torque command. When (torque command selection source) pn400 = 0, the internal torque command gives the torque, and the torque value is directly set by the parameter pn410. In this way, the internal torque can be given by writing the address 0x0410 through RS-485.

When pn400 = 1, it is an analog torque command, and the torque command is given according to the voltage connected to t-ref (cn1-9, cn1- 10) and the set value of pn405 (analog torque command gain). 101 SD700 Series Servo Technical Manual