Example: The factory default parameter Pn405=30 (3V corresponds to the rated torque). If the input voltage at the T-REF terminal is 1.5V, the torque command corresponds to 50%. If 3V is input, the torque command corresponds to 100%. 102 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn400 Torque command selection 0~1 1 - 0x0400 Immediately Select the command source of Torque control: 0 – Internal setting. 1 – Analog setting.
Pn404 Analog torque command filter time 0~ 655.35 0.00 ms 0x0404 Immediately The parameter is used to smooth the torque command when we apply a delay filter to the analog torque command (T-REF) input, usually it does not need to be changed. If the set value is too large, the responsiveness may decrease. So please set it up as we check the response. Pn405 Analog torque command gain 10~ 100 30 0.1V /Rated Torque 0x0405 Immediately This parameter is used to set the analog voltage value (T-REF) required for the rated torque of the servo motor. Note: Do not apply a voltage above -10V~10V. exceeding this range may damage the drive.
Pn406 Analog torque command invertion 0~1 0 - 0x0406 Immediately Analog voltage corresponds to the polarity setting of the torque command: 0- Positive polarity: Positive voltage corresponds to positive torque command. 1- Negative polarity: Positive voltage corresponds to negative torque command. Pn407 Analog torque command dead-zone range 0~3 0 V 0x0407 Immediately In analog torque control, even if the input command is 0V, the servo motor may rotate at a slight speed. This is because a slight deviation occurs in the command inside the servo. This deviation can be eliminated by setting an appropriate analog torque command dead-zone range.
Pn410 Internal torque command in torque control -500~ 500 0 % 0x0410 Immediately Set the internal torque command value during torque control.