VEICHI — SD700 User Manual 20230516

the setting value should not exceed 4Mpps. If the upper limit value is exceeded, A.511 (frequency division pulse output over speed alarm) will be output. When setting value is “4000”, and speed is 1600mm/s, = 1600000 = 4Mpps, 1.6Mpps < 4Mpps, so it can use this setting value. 5.8.7 Setting of Electronic Gear 5.8.7 Setting of Electronic Gear 5.8.7 Setting of Electronic Gear The setting range of the electronic gear ratio is as follows: 0.001 ≤ electronic gear ratio (B/A) ≤ 16778. When the setting range is exceeded, ER.040 (parameter setting abnormal alarm) will occur.

Calculation method of electronic gear ratio setting value ◆ Semi closed-loop control When the machine deceleration ratio of motor shaft and load side is n / M (when the motor rotates m turns, the load shaft rotates n turns), the setting value of electronic gear ratio can be obtained as following formula. Electric gear ratio ==Ч = Encoder resolution The encoder resolution can be confirmed by the servo motor model. The suffix D1 or D2 is 23 bit encoder, the suffix is Q1, Q2, R1, R2 is 17 bit encoder, the suffix is E1, E2 is 24 bit encoder.

Electric gear ratio ◆ Full closed-loop control == = 115 SD700 Series Servo Technical Manual Function Range Default Communication address When Parameter Unit code enabled Pn204 Electronic gear ratio (molecular) 0~1073741824 64 1 0x006/0x207 After restart Pn206 Electronic gear ratio (denominator) 0~1073741824 1 1 0x008/0x09 After restart Range