can choose whether automatic setting by Pn151 (Notch filter 2 automatic adjustment selection). The factory default is “Auto-tuning”. Only when the corresponding notch function is not needed, it is set to “Auto-adjust without auxiliary function”. 6.2.4 Related Parameters The parameters need to be set are shown as below when operating robust control function: 123 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn151 Notch filter 2 automatic adjustment selection 0x00~ 0x01 1 - 0x0151 Immediately 0-No automatic adjustment via auxiliary functions. 1-Automatic adjustment via auxiliary functions.
Parameter Name Pn175 Robust switch Pn104 First torque command filter Pn156 Second notch filter frequency Pn157 Second notch filter Q value