When speed feed forward and torque feed forward are input inertia identification is completed When the positioning complete width (Pn262) is small ! 1. When there is no command for intelligent setting, please change the adjustment mode and adjust with bandwidth setting or robust control when the adjustment fails for variable inertia load. 2. For intelligent setting, please set "Electronic gear ratio (Pn204/Pn206)" and "Positioning completion range (Pn262)" are set to the actual operating values. Otherwise, the adjustment may fail or the adjustment result may not match the actual operation result.
Cautions 6.4.3 Additional Notes Before the intelligent setting, you can set whether the related vibration suppression function is automatically set. The factory default is automatically set, please set the corresponding function switch to “Do not adjust automatically” before you want to change the value of the intelligent setting.
1) Vibration suppression function 127 SD700 Series Servo Technical Manual Function code Parameter Range Default Unit Communication When address enabled Pn140 IF suppression control options 0x00~ 0x11 0x0010 - 0x0140 Immediately The IF (intermediate frequency) suppression control function can effectively suppress the continuous vibration of about 100Hz ~ 1000 Hz that occurs when the control gain is increased. 0x1#: Automatically set IF vibration suppression frequency through intelligent setting and bandwidth setting. 0x0#: Not set automatically through intelligent setting and bandwidth setting, only manual setting. 0x#1: IF suppression frequency setting is valid. 0x#0:
IF suppression frequency setting is invalid. Pn150 Notch filter 1 automatic adjustment selection 0x00~ 0x01 1 - 0x0150 Immediately 0- Automatic adjustment without auxiliary functions. 1- Automatic adjustment through auxiliary functions. Pn151 Notch filter 2 automatic adjustment selection 0x00~ 0x01 1 - 0x0151 Immediately 0- Automatic adjustment without auxiliary functions. 1- Automatic adjustment through auxiliary functions.