VEICHI — SD700 User Manual 20230516

Immediately 2) Feed forward function In the factory setting mode, when the tuning mode is executed by “2”, “3”, “feedforward command (Pn109)”, “speed feedforward (VREF) input”, and “torque feedforward (T-REF) input “will become invalid. According to the system configuration, if you want to use “Speed feedback (V-REF) input”, “Torque feedforward (T-REF) input” and model tracking control from the upper device at the same time, set Pn249 = 1. ! When using model tracking control with this function, the model tracking control sets the optimal feedforward inside the servo.

Therefore, the "velocity feedforward (V- REF) input" and "torque feedforward (T- REF) input" from the upper unit are usually not used simultaneously. If the input feedforward is incorrect, it may cause overshoot, but please note that it can be used as necessary. Cautions 6.4.4 Related Parameters The parameters that may be changed when executing the intelligent setting function are as follows:

128 SD700 Series Servo Technical Manual Pn231 Low frequency vibration suppression function automatic adjustment selection 0x00~ 0x01 1 - 0x0231 Parameter Name Pn100 Rotary inertia ratio Pn101 First speed gain Pn102 First speed integral time constant Pn103 First position gain Pn104 First torque command filter Pn140 Intermediate frequency (IF) vibration suppression control selection Pn141 IFvibration suppression inertia modification Pn142 IF suppression frequency Pn143 IF suppressionattenuation gain