The response characteristics of the servo unit can be adjusted by setting the following servo gains. 133 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn100 Moment of inertia ratio 0~20000 100 % 0x0100 Immediately Moment of inertia ratio = load moment of inertia converted by motor shaft / rotor moment of inertia of servo motor *100%. Pn101 First speed gain 1~2000 40.0 Hz 0x0101 Immediately Determine the parameters of the speed loop responsiveness. If the response of the speed loop is low, it will become a delay factor of the outer position loop, and overshoot or vibration of the speed command occurs.
In the range where the mechanical system does not vibrate, the larger the setting, the more stable the servo system, and the better the responsiveness. Pn102 First speed integration time constant 0.15~512 20.00 ms 0x0102 Immediately In order to respond to small inputs, the speed loop contains integral elements. Since the integral element is a delay element for the servo system, when the time parameter is set too large, overshoot may occur, or the positioning time may be prolonged, resulting in poor response. Pn103 First position gain 1~2000 40.0 1/s 0x0103 Immediately The position loop response is determined by the position loop gain.
The higher the setting of the position loop gain, the higher the responsiveness and the shorter the positioning time. The position loop gain cannot be increased beyond the rigidity of the mechanical system. To increase the position loop gain to a larger value, the rigidity of the machine must be increased. Pn104 First torque command filter 0~655.35 1.00 ms 0x0104 Immediately Adjusting the parameters of the torque command filter may eliminate the machine vibration caused by the servo drive. The smaller the value, the better the responsiveness can be controlled. However, the conditions are restricted by the machine conditions.
Pn401 Torque command second-order low- pass filter cut-off frequency 100~5000 5000 Hz 0x0401 Immediately Use this parameter to set the cutoff frequency of the second-order torque filter. When this parameter is set to 5000, the function of the filter is invalid. Pn402 Torque command second-order low- pass filter Q value 0.5~1 0.50 1 0x0402 Immediately Use this parameter to set the Q value of the second-order torque filter. Increasing the Q value can improve the system responsiveness, but noise will be generated when the setting is too large.