VEICHI — SD700 User Manual 20230516

6.6.2 Gain Switching The gain switching function includes “manual gain switching” that uses an external input signal and “automatic gain switching” that automatically switches. By using the gain switching function, it could increase the gain and shorten the positioning time during positioning, and it could reduce the gain and suppress the vibration when the motor stops.

134 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn110 Gain switching mode selection switch 0x00 ~ 0x01 0 - 0x0110 Immediately The gain switching function includes two methods of “manual gain switching” using an external input signal and “automatic gain switching” that automatically switches. By using the gain switching function, it could increase the gain and shorten the positioning time during positioning, and it could reduce the gain and suppress the vibration when the motor stops. 0-Manual gain switching by external input signal of manual gain switching (G-SEL).

1-When the automatic switching condition is met (Pn111), it automatically switches from the first gain to the second gain; Otherwise, it switches back to the first gain. Pn111 Position control gain automatic switching condition 0x00 ~ 0x05 0 - 0x0111 Immediately Set the conditions for automatic gain switching: 0-positioning completion signal ON. 1-positioning completion signal OFF. 2-positioning proximity signal ON. 3-positioning proximity signal OFF. 4-position command is 0 after filter and pulse input is OFF. 5-position command pulse input ON. If the condition is met, it will switch to the second gain, otherwise it switches back to the first gain.

Pn112 Gain switching transition time 1 0~65535 0 ms 0x0112 Immediately After waiting for the waiting time from the time when the switching condition has been met, the first position loop gain is linearly changed to the second position loop gain during the switching transition time. Pn113 Gain switching transition time 2 0~65535 0 ms 0x0113 Immediately After waiting for the waiting time from the time when the switching condition has been met, the second position loop gain is linearly changed to the first position loop gain during the switching transition time. Pn114 Gain switching wait time 1 0~65535 0 ms 0x0114 Immediately