VEICHI — SD700 User Manual 20230516

feedforward command is connected to T-REF (CN1-9, 10). Related parameters 6.6.5 PI-P Switching When the control mode is speed control or position control, it could switch to PI-P control. When the control mode is mixed, it is valid only when it is switched to internal speed, analog speed and position mode. The PI-P switching can be switched by the digital signal “manual PI-P control signal (/P-CON)”. When the /P-CON signal is ON, P control is performed. The conditions for selecting automatic switching can also be selected by the parameter speed loop PI-P switching condition selection switch Pn131.

(1) Manual PI-P Control The signal is not configured in the factory default digital configuration. Therefore, the pin number configuration (0x05) needs to be performed by parameters Pn601 ~ Pn609. a) Configuration of manual PI-P Control b) The wiring of manual PI-P control The gain switching signal is a general configurable digital input. See “Sequence Input Circuit” for wiring details. (2) Automatic switching The switching condition of automatic PI-P switching is set by Pn131, and the switching condition value is set by Pn132, Pn133, Pn134, and Pn135.

By properly setting the switching conditions and condition values, overshoot during acceleration and deceleration can be suppressed and the settling time can be shortened. 138 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn124 Speed/position control selection (T-REF assignment) 0~1 0 - 0x0124 After restart Torque feedforward is a function to shorten the positioning time. Torque feedforward can be selected to given by external analog T-REF. 0-None. 1-T-REF as a torque feedforward input.

Pn405 Analog torque command gain 10~ 100 30 0.1V/ Rated torque 0x0405 Immediat ely Use this parameter to set the analog voltage value of (T-REF) required by servo motor rated torque. Note: Do not apply a voltage over -10V~10V. Exceeding this range may damage the servo drive.