139 SD700 Series Servo Technical Manual Speed Overshoot Speed Feedback Settling Time Command Overshoot Time Time Settling time Function Parameter Range Default Unit Communication address When code enabled Pn131 Speed loop PI-P switching condition selection switch 0x00 ~ 0x04 0 - 0x0131 Immediately The mode switch is a function that automatically performs P control and PI control switching. Setting the switching condition by this parameter and satisfying the corresponding switching condition value can suppress overshoot during acceleration and deceleration and shorten the settling time. 0 - Conditioned by internal torque command. 1 - Conditioned by speed command.

2 - Conditioned by acceleration. 3 - Conditioned by position deviation pulse. 4 - No mode switch function. Pn132 Speed loop PI-P switching condition (torque command) 0~800 200 % 0x0132 Immediately When the torque command exceeds the torque set by this parameter, the speed loop will be switched to P control, otherwise to PI control. Pn133 Speed loop PI-P switching condition (speed command) 0~ 10000 0 rpm 0x0133 Immediately When the speed command exceeds the speed set by this parameter, the speed loop will be switched to P control, otherwise to PI control.

Pn134 Speed loop PI-P switching conditions (acceleration) 0~ 30000 0 rpm/s 0x0134 Immediately When the speed command exceeds the acceleration set by this parameter, the speed loop will be switched to P control, otherwise to PI control. Pn135 Speed loop PI-P switching conditions (position deviation) 0~ 10000 0 comma nd unit 0x0135 Immediately When the position deviation exceeds the value set by this parameter, the speed loop will be switched to P control, otherwise to PI control.