7.4.2 Operating Procedure 7.5 Restore Factory Parameters (Fn003) 7.5.1 Overview The function is used to restore the parameters to the factory settings. ! 1. The parameter initialization must be executed in the servo OFF state. It cannot be executed in the servo ON state. The initialization of parameter settings must be performed in the servo OFF state. 2. To make the setting effective, the power to the servo unit must be turned back on after operation. 3. The values adjusted by Fn100, Fn101, Fn102, Fn103, and Fn104 will not be initialized when this function is executed.
Cautions 7.5.2 Operating Procedure DATA/SHIFT Long press Auxiliary function MODE/SET UP DATA/SHIFT Long press MODE/SET Any interface Auxiliary function Restore Factory recovery Enter Flash 2s confirmation Recovery 7.6 JOG Operation (Fn005) 7.6.1 Overview The JOG operation is a function that confirms the operation of the servo motor under speed control without connecting to a host device. To perform JOG operation, the following confirmation must be made in advance: The motor is in the enabled state and the Jog operation is invalid during the operation. The load inertia is suggested not more than 30 times of the motor inertia; otherwise it may cause large mechanical vibration.
Parameter Pn500, Pn310, Pn311 set the Jog speed, acceleration and deceleration time; 144 SD700 Series Servo Technical Manual Long press DATA/SHIFT Auxiliary function MODE/SET UP DL Ao Tn Ag /p Sr He Is Fs T MODE/SET Auxiliary Software Reset Any interface function reset Enter reset confirmation