default Jog speed is 500rpm. Cautions ! The overtravel prevention function is not available during JOG operation. The operating range of the machinery used must be considered while running. 7.6.2 Operating Procedure DATA/SHIFT Long press UP: Forward Any interface MODE/SET Auxiliary function UP JOG preparation JOG MODE/SET JOG enable ON DOWN:

Reverse DATA/SHIFT Long press MODE/SET JOG JOG ready JOG operation 7.7 Program JOG Operation (Fn006) 7.7.1 Overview Program JOG operation is a function that continuously runs with the preset operation mode, movement distance, movement speed, acceleration/deceleration time, waiting time, and number of 145 SD700 Series Servo Technical Manual Function code Parameter name Range D efaults Unit Communication address When enabled Pn500 Jog speed 0~1000 500 rpm 0x0500 Immediately Pn310 Speed command 0~ trapezoidal 0 ms 0x0310 Immediately acceleration 10000 time Set the time required to accelerate from 0 r/min to the maximum speed (corresponding to the motor model).

When the given speed is greater or less than the max speed, the actual acceleration time is calculated in proportion. 0~ 10000 0 ms 0x0310 Immediately Pn311 Speed command 0~ trapezoidal 0 ms 0x0311 Immediately deceleration 10000 time Set the time required to decelerate from the maximum speed (corresponding to the motor model) to 0 r/min. When the given speed is greater or less than the max speed, the actual deceleration time is calculated in proportion. 0~ 10000 0 ms 0x0311 Immediately Long press DATA/SHIFT