7.10.2 Operating Procedure DATA/SHIFT Long press Auxiliary function DATA/SHIFT Long press Any interface MODE/SET Auxiliary function UP Auxiliary function Enter manual offset DATA/SHIFT Short press Adjust the interface UP/DOWN adjustment confirmation Adjustment MODE/SET Adjust the interface 7.11 Current Offset Automatic Adjustment (Fn103) 7.11.1 Overview This function is only used when it is necessary to further reduce the torque ripple and other adjustments that need to be performed with higher precision, and usually does not require adjustment. ! 1. The automatic adjustment of the motor current detection signal offset must be performed while the servo is off. 2.
When the generated torque ripple is significantly larger than other servo units, perform automatic adjustment of the offset. Cautions 7.11.2 Operating Procedure Long press DATA/SHIFT Auxiliary function UP DATA/SHIFT Long press MODE/SET Any interface MODE/SET Auxiliary function Current adjustment automatic offset Enter adjustment automatic offset confirmation Adjustment Flash2s 7.12 Current Offset Manual Adjustment (Fn104) 7.12.1 Overview This function is used only when the torque ripple is still large after the motor current detection signal offset automatic adjustment (Fn103) is executed. 148 SD700 Series Servo Technical Manual