10 Function Code Instructions 10.1 Pn0 Group Basic Control Related Parameters 226 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When enabled code address Pn000 Control mode selection 0~11 0 - 0x0000 After restart 0-Position mode: The position of the motor is controlled by the pulse sequence position command. The position is controlled by the number of input pulses, and the speed is controlled by the frequency of the input pulse that is used in the place where positioning action is required. 1-1-Analog speed: The servo motor speed is controlled by the analog voltage speed command. 2-2-Torque Mode:
The output torque of the servo motor is controlled by the analog voltage torque command/internal torque command which is used to output the necessary torque (pressing action, etc.). 3-3-Internal speed: The speed is controlled by three internally set speeds set in the servo unit. When this control method is selected, no analog voltage is required. 4-4-Internal Speed Analog Speed: Switch control mode via ON/OFF of switch/SPD-A and /SPD-B. 5-5-Internal Speed Position Mode : Switch control mode via ON/OFF of switch/SPD-A and /SPD-B. 6-6-Internal Speed Torque Mode: Switch control mode via ON/OFF of switch/SPD-A and /SPD-B. 7-7-Position Mode Analog Speed:
ON/OFF switching control mode by (C-SEL) signal switching. 8-8-Position mode Torque mode:ON/OFF switching control mode by (C-SEL) signal switching. 9-Torque mode Analog speed: ON/OFF switching control mode by (C-SEL) signal switching. 10-Analog speed Speed mode for zero function: When controlling speed, zero fixed function can be used. 11-Position mode Position mode when command pulse inhibit: The command pulse inhibit function can be used when controlling the position. See “selection of hybrid control mode” for specific switching sequence. 16-EtherCAT mode (-EA model, this parameter defaults to 16). Pn001 Internal enable 0~1 0 - 0x001 Immediately 0-Enable OFF. 1-Enable ON.
Pn002 Motor rotation direction selection 0~1 0 - 0x0002 After restart Facing motor end: 0-Counterclockwise is forward. 1-Clockwise direction is forward. Pn003 Default monitoring parameters 0x0~ 0xfff 0xfff - 0x0003 Immediately Set the monitoring parameters that are displayed by default after power-on. The setting values are detailed in the monitoring parameters. 0xfff indicates that the monitoring parameters are not displayed and the system status is displayed. Note: The alarm is displayed first when the alarm is displayed. The setting parameter cannot be displayed normally. Pn004 Servo OFF and stop method selection when type 1 alarm occurs 0~2 0 - 0x0004 After restart