VEICHI — SD700 User Manual 20230516

227 SD700 Series Servo Technical Manual 0- Stop motor by DB. 1- Stop the motor through the DB and then release the DB. 2- Do not use DB to keep the motor free. Note: DB (Dynamic Brake) is an emergency stop function. If the servo motor is started or stopped by ON/OFF power supply or servo ON in the state that the command is input, the DB circuit will frequently operate, which may cause the internal components of the servo unit to deteriorate. Please execute start and stop of the servo motor with speed input command or position command. Pn005 Second type alarm stop method selection of servo generation 0x00~ 0x01 0 - 0x0005 After restart 0- Zero speed stop:

Set the speed command to “0” and perform a quick stop. 1- Same as Pn004 stop method. Pn006 Override warning checkout selection 0~1 0 - 0x0006 After restart 0-No overtravel warning when limit is checked. 1-Overtravel warning is detected when the limit is checked. Pn007 Stopping method selection at servo overtravel (OT) 0~2 0 - 0x0007 After restart Set the stop mode and status after stop when servo overtravel occurs: 0- Same as Pn004 stop method. 1- Use the torque set by Pn053 as the maximum value, and enter the locked state after decelerating to stop. 2- Use the torque set by Pn053 as the maximum value, enter the free state after decelerating to stop.

Pn008 Servo lock time after electromagnetic brake holding 0~50 0 0ms 0x0008 Immediately When the servo motor is enabled but not running(stop state) and the brake (/BK) signal and the servo ON (/S-ON) signal are off at the same time, setting this parameter can change the time from the brake (/BK) signal OFF to the actual non-power input status of the motor. Note: The brake delay time is slightly different. When this parameter is set, the motor can be prevented from the slight moving by the weight or the external force of the vertical-axis mechanical movement.

Pn009 Electromagnetic brake holding time delay 10~100 50 0ms 0x0009 Immediately The servo motor won’t be powered when the Servo OFF/Alarm/Main circuit OFF occur during the rotation. By setting this parameter and Pn010 (any one is met), the output timing of the brake signal (/BK) OFF can be adjusted. Note: The relevant logic is described in “Keep brake action”. Pn010 Electromagnetic brake brake delay release speed 0~ 10000 100 rpm 0x0010 Immediately See the description of “Electromagnetic brake brake delay” for details.

Pn012 External regenerative resistor power 0~ 65535 0 10W 0x0012 Immediately When connecting an external regenerative resistor, the regenerative resistor power should be set to a value that matches the allowable capacity of the connected external regenerative resistor. The setting differs depending on the cooling condition of the external regenerative resistor. Note: Refer to “Setting the regenerative resistor” for details. Pn013 External regenerative resistor 0~ 65535 0 Ω 0x0013 Immediately When connecting an external regenerative resistor, the regenerative resistor value should be set to the value matching the connected external regenerative resistor. Note:

The minimum regenerative resistance of each power section could be different. Please refer to “Set regenerative resistor” for details. Otherwise, the internal components of the servo unit may be damaged.