228 SD700 Series Servo Technical Manual Pn015 Overload warning value 1~100 20 % 0x0015 After restart Setting this parameter can change the overload warning detection time. Note: The overload alarm detection time is detailed in “Overload alarm”. Pn016 Motor overload detection base current derating setting 10~100 100 % 0x0016 After restart This parameter can change the motor current threshold for calculating the overload alarm, which can shorten the overload alarm detection time. Note: This value is invalid when the motor current is rated above 200%.
Pn030 Reserved 0~ 65535 0 - 0x0030 Immediately Pn031 Parameter modification operation lock 0~1 0 - 0x0031 After restart 0-Allow panel parameters modification. 1-Prohibit panel parameters modification. Pn040 Method to use absolute encoder 0~1 0 - 0x0040 After restart 0-Use an absolute encoder as an absolute encoder: If the motor is an absolute multi-turn encoder, setting this parameter to 0 can use the multi-turn absolute function. 1-Use an absolute encoder as an incremental encoder:
When used as an incremental encoder, the position won’t be recorded when power-off and warning or alarm, corresponding to multiple revolutions, won’t happen either when the battery is undervoltage or the drive is de-energized. Pn041 Absolute encoder battery alarm/warning selection 0~1 0 - 0x0041 After restart 0- Set the low battery voltage as a fault: Monitor the battery status within 4 ~ 9 seconds after the driver is powered on / reset, and the undervoltage alarm (Er.830) will be reported when the undervoltage. Over time will not be detected. 1- Set the low battery voltage as a warning: Undervoltage (below 3V) will be reported as an under voltage alarm (Al.930).
It will always monitor the battery voltage and can be self-recovery, enable is out of restriction. Function Parameter Range Default Unit Communication When enabled code address Pn044 Full closed loop application related selection 0~51 1 - 0x0045 After restart 0: Encoder pulse frequency division output, grating ruler power supply is valid, and grating ruler signal is not filtered. 1: Pulse output, grating ruler power supply is valid, and grating ruler signal is not filtered. 2: Encoder pulse frequency division output, grating ruler power supply is invalid, and grating ruler signal is not filtered. 3:
Pulse output, the grating ruler power supply is invalid, and the grating ruler signal is not filtered. 4: Encoder pulse frequency division output, grating ruler power supply is valid, 0MHz ~ 4MHz filtering. 16: Grating ruler pulse output, grating ruler power supply is valid, 0MHz ~ 4MHz filtering. 18: Encoder pulse frequency division output, grating ruler power supply is invalid, 0MHz~4MHz filtering. 19: Grating ruler pulse output, grating ruler power supply is invalid, 0MHz ~ 4MHz filtering. 32: Encoder pulse frequency division output, grating ruler power supply is effective, 0MHz ~ 1MHz filtering. 33:
Grating ruler pulse output, grating ruler power supply is effective, 0MHz ~ 1MHz filtering. 34: Encoder pulse frequency division output, grating ruler power supply invalid,